Markets · Plant utilities
Find out why maintained pumps still fail.
Chilled water, cooling, HVAC and compressed air keep the plant running. Their pumps, motors and fans are maintained and read on a route, and some faults still come back. Our sensors fill the gap between readings, and we tell you which machine needs attention and why.
Open to proofs of concept
What you get
The answer, and what it is worth.
Every market starts from the question your current data cannot answer. Here is what we tell you, and the value behind it.
What we tell you
- Which pumps, motors and fans are changing condition, and at what speed and load
- The trend between your route readings
- How each machine's condition affects the service it supports
- Which machine to inspect first
Where you save
- Fewer repeat failures on the same machines
- Repairs planned before the service drops
- Maintenance time spent where it counts
Your route readings stay. We fill the weeks between them.
Our interpretation
Batch 14 off your in-spec profile
- Stage
- Heating, 2 of 3
- Seen
- Heating 9 minutes slower than your in-spec batches
- Next step
- Check the heating supply and jacket before the next addition
Where you saveFewer out-of-spec batches, and the reason behind them
What we measure
The signals behind the answer.
We pick the signals the job needs and connect the records you already hold.{d.get('mnote', '')}
| Signal | Where it goes | What it tells you |
|---|---|---|
| Vibration | Bearing housings of pumps, motors and fans | The condition trend of each machine |
| Temperature | Bearings and casings | Heat that builds as a fault develops |
| Operating state | Speed, load and duty, from your control or building system | Context, so a load change is not read as a fault |
| Your data | Maintenance history and route readings | What has failed before, and what was found |
How the answer is built
From raw signal to a decision.
Four steps, run by our models and our engineers. Each one is logged against the asset or batch it belongs to.
- 01Scope
Pick the machines behind one service, such as chilled water, and the failures that matter.
- 02Combine
Condition from our sensors is lined up in time with speed, load and duty.
- 03Learn normal
We learn what normal looks like for each machine at each speed and load.
- 04Review
Changes that speed and load cannot explain go to maintenance, with the evidence.
What arrives
An answer your team can act on.
Every answer says what happened, where, why it matters and what to do next, with its evidence, a confidence level and the person it goes to.
The pilot
Scoped first
Selected pumps and motors behind one service, such as chilled water. The aim is simple: show your maintenance team the condition data earns its place before anything grows.
Book a site auditExample answer
- What happened
- Vibration on Pump 4 rising over five weeks
- Where
- Chilled water Pump 4, drive end bearing housing
- Why it matters
- The rise holds at the same speed and load, so operation does not explain it
- What to do next
- Take a higher rate capture on that bearing and plan an inspection
- Evidence
- Measured vibration against the level expected at that speed
- Confidence and owner
- Medium confidence. Owner: maintenance lead. Reply due this week
Questions
What plant utilities teams ask first.
- We already run condition monitoring.
- Keep it. We read your route data alongside ours and add the operating context between visits.
- Does this replace route readings?
- No. It shows the trend between routes and helps your analyst decide where to go first.
- What about clean or hazardous areas?
- The rules for each area are reviewed before anything is fitted. Our nodes are not certified for hazardous areas, so there we connect certified instruments.
Next step
Put our sensors on the pump that keeps failing.
A site audit shows where data is missing today, what it would tell you, and which machine or process to start with.